Lead Acid Battery Testing Machine for Valve Open and Close Pressure

Product Details
Customization: Available
After-sales Service: 24 Hours Response Speed
Warranty: One Year Warrant
Diamond Member Since 2018

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
10000000 RMB
Plant Area
50000 square meters
  • Lead Acid Battery Testing Machine for Valve Open and Close Pressure
  • Lead Acid Battery Testing Machine for Valve Open and Close Pressure
Find Similar Products

Basic Info.

Model NO.
BETTER
Test Region
Valve Pressure
Application
Lead-acid Battery
Customized
Customized
Gas
Use an External Air Compressor to Compress Gas (So
Pressure Range
Adjustable
Testing Time
Adjustable
Inflation Speed
Adjustable
Test Jig Required
One Model of Middle Cover Require Two Test Jig
Test Jig
Each Set Is Divided Into Upper and Lower Molds
Transport Package
Export Standard
Specification
Two groups 12 channels, each group 6 channels, ran
Trademark
Better
Origin
China

Product Description

Safety valve opening pressure testing equipment

Lead Acid Battery Testing Machine for Valve Open and Close Pressure

Specification:
1. Two groups 12 channels, each group 6 channels, range 0~100KPa.
2. Valve opening test 1st: Add air at a slow speed, and check whether the air pressure at the first opening is within the range of 30KPa~55KPa, (above 55KPa is defective product); Evacuate the gas in the pipe, open the valve for the second time after an interval of two minutes (adjustable time, 0~999 seconds) and check whether the opening pressure is within the range of 30~45KPa (lower than 30KPa, or higher than 45KPa is a defective product)
3.After the second valve opening test, stop adding gas and let the safety valve discharge the gas autonomously for 1 min. When the air pressure is stable, it can be recorded as the closed valve pressure value. The air pressure is within the range of 15~35KPa, (less than 15KPa, or higher than 30KPa is a defective product)
4. After the safety valve has completed the above tests, do the acid immersion test, and the valve pressure test is still required after the acid test. Method: add air at a slow speed, and check whether the opening pressure is within the range of 30KPa~55KPa (lower than 30KPa, or higher than 50KPa is a defective product); stop adding gas and let the safety valve discharge the gas autonomously for 1 min. When the air pressure is stable, it can be recorded as the closed valve pressure value. The air pressure is within the range of 15~35KPa, (less than 15KPa, or higher than 30KPa is a defective product)
5. One model of middle cover require two test jig
6. Gas: Use an external air compressor to compress gas (source of gas must clean)
Remark: Pressure range, testing time, inflation speed can be set and adjusted.
Test jig:
One type of middle cover, requires 1~2 sets of test jig (each set is divided into upper and lower molds)


 

--------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------
 


Lead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close PressureLead Acid Battery Testing Machine for Valve Open and Close Pressure

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now