1. Instruction and Classification
The Drying Machine for Charged Plates is suitable for the drying section for charged plates after plate formation.
According to different grid structure design, it can be divided into: Flat-hanging drying machine and Slant-hanging drying machine.
According to different use of energy, it can be divided into: fuel heating drying machine, gas heating drying machine, electricity heating drying machine, steam and electricity heating drying machine and thermal oil heating drying machine.
2. Main Technical Parameters:
1) Main transmission:
It adopts frequency control transmission, the transmission speed is: 0.5-1.4m/min (can be adjusted by the frequency converter), every minute can dry 54-137pcs uncut plates (according to the condition of plate).
The main transmission power: 2.2Kw
2) Hot air circulation blower (3pcs)
Blower motor power: 7.5Kw Air Amount: Q=13,000m3/h Air pressure: 1,000Pa
3) Waste extraction (3pcs)
Extraction motor power: 1.1Kw Air Amount: Q=3,800m3/h Air pressure: 300Pa
4) Dryer temperature:
Temperature range: 110~150ºC (Each section's temperature can be set separately)
5) Appearance and inner cavity dimensions:
Appearance (mm): 23,000 (L) * 1,220 (W)
Height for fuel / gas heating drying machine is 2,350mm
Height for steam and electricity / thermal oil / electricity heating drying machine is 2,450mm
Among them, the length of the heating part is: 18,000mm, feeding part is 2,500mm, plate collection part is 2,500mm, distance between the guide rail is 620mm, center distance of the chain is 670mm.
6) Equipment Weight: 11Tons
7) Axial flow fan (Totally 8pcs: 6pcs for front part + 2pcs for rear part)
Fan power: 0.37Kw Air Amount: Q=3,000M3/h Air pressure: 160Pa
3. Different Heating Methods
Machine |
Heating Method |
Power |
Energy Configuration |
Remark |
Drying Machine for Charged Plates |
Electricity heating |
28Kw |
Stainless steel heating tube: 204Kw |
|
Steam and Electricity heating |
28Kw |
The radiator area: 250c square meter; Heating tube: 84Kw |
Stainless steel heating tube |
Gas heating |
28Kw |
Burner Max. output power: 205Kw |
Single section fire with proportional control |
Fuel heating |
28Kw |
Burner Max. output power: 166Kw |
Double-section fire |
Thermal oil heating |
28Kw |
The radiator area: 250 square meter; Heating tube: 84Kw |
|
-----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------